Umpire's Practical Tear Gas Removal Guide for Homeowners

This guide provides a practical approach to safely and effectively removing tear gas residue from your home using the Airbotx hydroxyl generator and Benefect Quantum Chemical Residue Remover.

IMPORTANT SAFETY NOTICE

Tear gas is a chemical weapon that can cause ongoing health issues if not properly removed. Professional remediation is always the safest option. This guide is for situations where you need to take immediate action.

Equipment Needed

Safety Equipment (Essential)

  • HAZMAT suit or disposable protective coveralls
  • Full-face respirator with appropriate filters for chemical agents
  • Chemical-resistant gloves
  • Boot/shoe covers

Cleaning Supplies

  • Benefect Quantum Chemical Residue Remover
  • HEPA vacuum
  • Clean microfiber cloths
  • Disposable cleaning rags
  • Plastic sheeting
  • Plastic garbage bags (heavy-duty)
  • Duct tape
  • Extension cords

Equipment

  • Airbotx hydroxyl generator (model 390X recommended for severe contamination)
  • Fans for ventilation

Step-by-Step Removal Process

Phase 1: Emergency Response

  1. Evacuate the affected area immediately if tear gas was recently deployed.
  2. Seek medical attention if experiencing severe symptoms.
  3. Ventilate the home by opening all windows and doors.
  4. Turn off your HVAC system to prevent spreading contamination throughout the home.

Phase 2: Preparation

  1. Don protective equipment before entering the contaminated area.
  2. Assess the damage and identify heavily affected areas.
  3. Set up containment zones using plastic sheeting to prevent cross-contamination between cleaned and uncleaned areas.
  4. Create an outdoor cleaning station for items that can be removed from the home.
  5. Take photos for insurance purposes if applicable.

Phase 3: Initial Cleanup

  1. Remove all porous materials that are heavily contaminated:
    • Carpet and padding
    • Curtains and drapes
    • Upholstered furniture
    • Paper products
    • Clothing (if salvageable, place in sealed bags for separate laundering)
  2. HEPA vacuum all surfaces to remove particles before wet cleaning.
  3. Deploy the Airbotx hydroxyl generator:
    • Place the unit in the most contaminated area
    • Ensure adequate airflow
    • Keep the area cool (heat can cause residue to become airborne)
    • Allow the unit to run continuously

Phase 4: Deep Cleaning

  1. Apply Benefect Quantum Chemical Residue Remover:
    • The product is ready to use without dilution
    • Apply directly to all hard surfaces (walls, floors, counters)
    • Work in small sections (approximately 15ft × 15ft)
    • Allow to dwell for 10 minutes as specified by manufacturer
    • Wipe surfaces with clean microfiber cloths
    • Use separate cloths for each area to prevent cross-contamination
  2. Clean from top to bottom:
    • Start with ceilings
    • Move to walls
    • Finish with floors
  3. Clean all hard-surface contents:
    • Electronics may need special attention
    • Glass and metals can be thoroughly cleaned with Quantum
    • Remember to clean inside cabinets and drawers
  4. Dispose of all cleaning materials properly in sealed plastic bags.

Phase 5: Secondary Treatment

  1. Continue running the Airbotx hydroxyl generator for 24-48 hours after cleaning.
  2. Re-clean any areas where tear gas effects remain detectable.
  3. Once the main living areas are safe, have your HVAC system professionally cleaned before turning it back on.

Phase 6: Final Steps

  1. "Sniff test" - Have different people check for any remaining tear gas odor or effects. If detected, repeat the cleaning process.
  2. Bring in professional help if residue persists after multiple cleaning attempts (Or, call Umpire at 703-665-1129 to do it from the beginning!).
  3. Continue running the Airbotx hydroxyl generator for several days to ensure all airborne particles are neutralized.

Special Considerations

Electronics

  • Unplug and clean exteriors with lightly dampened cloths
  • Allow to thoroughly dry before powering on
  • Consider professional cleaning for valuable electronics

Fabrics and Soft Materials

  • Washable items: Launder multiple times with regular detergent
  • Non-washable items: May need professional cleaning or disposal

Children and Pets

  • Keep children and pets away from the affected area until cleaning is complete
  • Clean their toys and belongings with special care
  • Consider temporarily relocating until the home is fully decontaminated

Recommended Timeline

  1. Immediate (0-24 hours): Ventilation, removal of heavily contaminated materials, initial deployment of Airbotx
  2. Day 1-2: Deep cleaning with Benefect Quantum
  3. Day 3-5: Continued hydroxyl treatment, secondary cleaning as needed
  4. Day 5-7: HVAC cleaning, final assessment

When to Call Professionals

  • If you experience persistent health issues
  • If the contamination is severe or widespread
  • If you lack proper safety equipment
  • If multiple cleaning attempts don't resolve the issue

Remember that tear gas residue can cause ongoing health issues if not properly removed. When in doubt, consult with professional remediation services that specialize in chemical decontamination.

Contact Information

The information in this guide is compiled using Claude with Stephen's experience from industry sources and regulatory documents. Call Umpire Mitigation at 703-665-1129 anytime with questions or to chat about how we can help you.

Never wonder who to call again.